Customization: | Available |
---|---|
Number of Charging Interfaces: | One Pile with Multiple Charges |
Location: | Public Use |
Still deciding? Get samples of US$ 500/pcs
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Item | Parameters | Remark |
Operating Voltage(AC) | 285~475V,rated voltage380V | See input voltage/output power 1.3.3-1 |
Input Frequency(HZ) | 45~55 | |
Power Factor | Full load≥0.99 | |
THD | Full load≤5% | |
Standby Power Consumption |
<12W |
Item | Parameter | Remark |
Output Voltage Range(DC) | 150~1000V | |
Max output current(A) | 120 | |
Output constant power interval | 250~500VDC,500~1000VDC | |
Output current limit range | Max limit current is120A,limit current point can be set between 2~120A | See output voltage/current curve 1.3.3-2 |
Voltage Stabilization Accuracy | ≤±0.5% | |
Current Stabilization Accuracy | ≤±1%(load current is in the range of 20%~100%) | |
Effective value coefficient of output ripple | ≤±0.5% | |
Current sharing imbalance for modules in parallel | ≤±5%(parallel average current should be more than 5A) | |
Peak efficiency | ≥95.5% | |
Soft start time(S) | 3~8 | |
When output, prevent current rewinding | Support | |
Communication Protocol | CAN |