Module Technical Specification:
Input Features
| Item | Parameters | Remark |
| Operating Voltage(AC) | 266~494, rated voltage 380 |
See input voltage/output power curve 1.3.3-1 |
| OperatingVoltage (DC) | 400-860 | Normal operating range input 600-800DC can output 20kw See 1.3.3-2 for input voltage/output maximum power curve |
| Input Frequency(HZ) | 45~55 | In case of AC input |
| Power Factor | Full load≥0.99 | In case of AC input |
| THD | Full load≤5% | In case of AC input |
| Standby Power Consumption |
<10W |
Output Features
| Item | Parameters | Remark |
| Output Voltage Range(DC) | 200~750 | |
| Max Output Current(A) | 50A(AC) 33A (DC) |
|
| output characteristic | When 600~750VDC is output, the output power is 30KW. When the output is 400~500VDC, the constant current 50A(≥20KW) ambient temperature is higher than the 40 power limit | Ac input See 1.3.3-3 for output voltage/output current curve |
| output characteristic | When 606~750VDC is output, the maximum output power is 20KW. | Dc input See 1.3.3-4 for output voltage/output current curve |
| Voltage Stabilization Accuracy | ≤±0.5% | Output voltage 300-750V Voltage stabilization accuracy below 300V and within 2 V. |
| Current Stabilization Accuracy | ≤±1%(The load current is in the range of 20%~100%) | |
| Effective Value of Output Ripple |
≤±0.5% | Output voltage 300-750V |
| Current Sharing Imbalance for modules parallel |
≤±5%(parallel average current should >5A) |
|
| Peak Efficiency | ≥95.5% | |
| Soft Start Time(s)(S) | 3~8 | |
| Output prevent reverse irrigation |
Support | |
| Communication bus protocal | CAN |
1.3.3-1 Input voltage /output power curve

1.3.3-1 Input voltage /output power curve
CE CERTICIFICATION: