| Item | Parameters | Remark |
| Operating Voltage(AC) | 285~475V,rated voltage380V | See input voltage/output power 1.3.3-1 |
| Input Frequency(HZ) | 45~55 | |
| Power Factor | Full load≥0.99 | |
| THD | Full load≤5% | |
| Standby Power Consumption |
<12W |
| Item | Parameter | Remark |
| Output Voltage Range(DC) | 150~1000V | |
| Max output current(A) | 120 | |
| Output constant power interval | 250~500VDC,500~1000VDC | |
| Output current limit range | Max limit current is120A,limit current point can be set between 2~120A | See output voltage/current curve 1.3.3-2 |
| Voltage Stabilization Accuracy | ≤±0.5% | |
| Current Stabilization Accuracy | ≤±1%(load current is in the range of 20%~100%) | |
| Effective value coefficient of output ripple | ≤±0.5% | |
| Current sharing imbalance for modules in parallel | ≤±5%(parallel average current should be more than 5A) | |
| Peak efficiency | ≥95.5% | |
| Soft start time(S) | 3~8 | |
| When output, prevent current rewinding | Support | |
| Communication Protocol | CAN |